URT/EC 051÷212 S/IK

Double Skin packaged Roof Top units with Inverter Scroll compressors and EC Inverter Plug-Fans

_icona_clint_solo_raffreddamento_2024.png _icona_clint_solo_raffreddamento-riscaldamento_2024.png _icona_clint_compressore_scroll_inverter_2024.png _icona_clint_fan_plug_EC_inverter_2024.png _icona_clint_solution_doppio_pannello_2024.png _icona_clint_refrigerant_R410A_2024.png

The double skin packaged Roof Top units of this series are the ideal solution for air conditioning of wide surfaces such as shopping malls and restaurants, canteens or for industrial areas. Those units feature Inverter Scroll compressor with R410A refrigerant and EC Inverter Plug-Fans. The highest efficiency at partial loads is guaranteed by the Inverter Scroll technology on compressor since its power is varied proportionally to the requested thermal load.
Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in Cooling only and Reversible Heat Pump version.
The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards.
The units are compliant to the ErP Regulation.

Versions

  • URT/EC - Cooling only with EC Inverter Plug-Fans
  • URT/EC/WP - Reversible heat pump with Plug-Fans EC Inverter

Power range

  • 58.0-252 kW
  • 17.0-72.0 Ton

Features

  • Structure of base perimeter made of steel sheet elements galvanised. Frame made of extruded aluminium alloy profiles connected by 3 way joints. Assembling of the base to the frame is of dual support and grants the walking on the base panels installation without sticking out screws. 50mm thick sandwich panels made of prepainted steel sheet; water proofing granted by gaskets having shape memory for perfect seal up even after repeated removals. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets.
  • DC INVERTER Scroll and ON-OFF Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser and evaporator with copper tube and aluminium finned coil.
  • EC INVERTER PLUG-FAN delivery fan with high energy efficient reversed blades with external rotor motor and electronic speed adjustment for easy adaptation to plant features.
  • Electronic expansion valve.
  • R410A refrigerant.
  • Electrical board includes: door interlocking isolator, fuses, thermal protection relays on compressors, thermocontacts for the fans of the condensing unit and contactors for the fan motors of the air handling unit.
  • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -20°C.
  • Microprocessor for the automatic control of the unit.

Factory fitted accessories

  • IM Automatic circuit breakers
  • SL Unit silencement
  • RFM Cooling circuit shut-off valve on discharge line
  • RFL Cooling circuit shut-off valve on liquid line
  • ECA EC Inverter fans on condensing section
  • TXC Condensing coil with pre-coated fins
  • TXE Evaporating coil with pre-coated fins
  • FT/M6 Soft bag filters efficency ePM10 70% (M6)
  • FT/M7 Soft bag filters efficency ePM2.5 70% (F7)
  • FT/M8 Soft bag filters efficency ePM1 70% (F8)
  • FT/R6 Rigid bag filters efficency ePM10 70% (M6)
  • FT/R7 Rigid bag filters efficency ePM1 50% (F7)
  • FT/R8 Rigid bag filters efficency ePM1 70% (F8)
  • FT/E Electrostatic filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • AT/C Control adjustment of the air flow according to the load
  • WS2 Hot water coil with 3-Way valve
  • EHG Electrical heater with step regulation
  • SSA Active sanitation systems for air and rooms
  • PF Differential pressure switch filters control
  • SB Fire sensor
  • SC Smoke sensor
  • IS Modbus RTU protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • CP Potential free contacts
  • RP Coils protection metallic guards
  • MN High and low pressure gauges

Loose accessories

  • CR Remote control panel
  • AG Rubber shock absorbers
051061071081091101111131152172212
CoolingCooling capacity (1)kW57,965,877,687,498,6113129145168198252
Absorbed power (1, 2)kW19,421,824,626,230,837,840,443,354,661,585,1
Cooling (EN14511)SEER (3)4,574,614,784,814,694,534,524,664,424,294,31
Energy Efficiency (3)%180181188189185178178183174169169
HeatingHeating capacity (4)kW60,267,276,888,6101115133151173204262
Absorbed power (4, 2)kW16,817,920,222,825,232,234,040,045,750,470,5
Heating (EN14511)SCOP (5)3,463,513,623,603,573,403,443,523,563,553,47
Energy Efficiency (5)%135137142141140133135138139139136
Air treatment sectionAir flowm³/s2,673,304,054,054,845,496,326,328,209,7912,31
Available static pressurePa250250250250250250250250250250250
Fan11222222244
FilterTipoG4G4G4G4G4G4G4G4G4G4G4
Condensing sectionCompressor22222222444
Refrigerant circuits11111111222
Capacity stepsSteplessSteplessSteplessSteplessSteplessSteplessSteplessSteplessSteplessSteplessStepless
Fan22222244446
Hot water coilHeating capacity (6)kW85100125125150175200200250300350
Air pressure dropsPa3031313131303636353557
Water flow (6)l/s2,032,392,992,993,584,184,784,785,977,178,36
Water pressure dropskPa4547484849445151535745
Water connections"G1"­½1"­½1"­½1"­½1"­½2"2"2"2"2"-½2"-½
Electrical heaterPower supplyV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Heating capacitykW1521272727414141414855
Max absorbed currentA2230393939595959596979
Steps22222444444
Electrical characteristicsPower supplyV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Max. running currentA555668688086104104140160207
Max. starting currentA138139190190203253245245272327395
Sound pressureSTD version (7)dB(A)6869686970727474737373
With SL accessory (7)dB(A)6566656667697171707070
WeightsTransport weightkg9901050115012501260145018101860223024003180
Operating weightkg9751035113512351245143017901840221023803150
Weight EC/WP versionsTransport weightkg10901160127013801390160019902050245026403500
Operating weightkg10751145125513651375158019702030243026203470

Dimensions

051061071081091101111131152172212
LSTDmm34303430359035903590405047704770477047706800
WSTDmm22002200220022002200220022002200220022002200
HSTDmm21002340234023402340234023402340234025102510

Notes

  • 1 Evaporator inlet air temperature 27 °C d.b./19 °C w.b.; ambient air temperature 35 °C.
  • 2 Excluded the power absorbed by fans of air treatment section.
  • 3 Seasonal energy efficiency of cooling. According to EU Regulation n. 2016/2281.
  • 4 Condenser inlet air temperature 20 °C, ambient air temperature 7 °C d.b./6 °C w.b.
  • 5 Seasonal energy efficiency of heating with average climatic conditions. According to EU Regulation n. 2016/2281.
  • 6 Inlet air temperature 20 °C, water temperature 70/60 °C.
  • 7 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.
  • N.B. (1) Weights of WP version are specified on technical brochure.