JWA/WP 051÷172 S/K/P/A

High efficiency air cooled dedicated Heat Pumps for medium temperature hot water production (up to 55°C) with axial fans, Scroll compressors and plate exchanger

_icona_clint_solo_raffreddamento-riscaldamento_2024.png _icona_clint_compressore_scroll_2024.png _icona_clint_fan_assiale_2024.png _icona_clint_exchanger_plate_2024.png _icona_clint_solution_A_class_heating_2024.png _icona_clint_refrigerant_R410A_2024.png _icona_clint_refrigerant_R452B_2024.png _icona_clint_refrigerant_R454B_2024.png

The reversible Heat Pumps of the JWA/WP 051÷172 S/K/P/A series, with R410A refrigerant, are designed for medium-sized service sector or industrial ambients.
They are used, combined with terminal units, for the heating or air conditioning of the rooms and are supplied with Modbus RTU protocol through RS485 serial interface.
Equipped with axial fans, Scroll compressors and plate exchanger, even in the super silent version, these units can be completed by a hydraulic circuit with tank, with pump, with tank and pump.
A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series.
Are available as option the new EC Inverter fans with high available static pressure and efficiency for indoor ducted installation.

The units are designed for medium temperature hot water production (up to 55°C).
The units are compliant to the ErP Regulation.
On request, units can be supplied with R452B or R454B refrigerant.

Versions

  • JWA/WP - Reversible Heat Pump
  • JWA/WP/SSL - Super silenced reversible Heat Pump

Power range

  • 56.0-197 kW
  • 16.0-56.0 Ton

Features

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Axial fans directly coupled to an electric motor with external rotor.
  • Condenser made of copper tubes and aluminium finned coil.
  • Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side in 051÷131 models; with two independent circuits on the refrigerant side and one on the water side in 152÷172 models, complete with water differential pressure switch. On the units it is always installed an antifreeze heater.
  • R410A refrigerant. On request R452B or R454B refrigerant.
  • Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
  • Functioning in heating mode with outside air temperature down to -15 °C.
  • Microprocessor control and regulation system.

Factory fitted accessories

  • IM Automatic circuit breakers
  • RE Adjustable minimum/maximum voltage and phase control relay
  • SL Unit silencement
  • RFM Cooling circuit shut-off valve on discharge line
  • RFL Cooling circuit shut-off valve on liquid line
  • CC Condensing control down to -20 °C
  • BT Low water temperature kit
  • EC EC Inverter fans
  • ECH EC Inverter fans with high available static pressure
  • DS Desuperheater
  • RT Total heat recovery
  • TX Coil with pre-coated fins
  • SI Inertial tank
  • PS Single circulating pump
  • PSI Inverter single circulating pump
  • PD Double circulating pump
  • PDI Inverter double circulating pump
  • GS Single circulating pump gasket for glycol >30%
  • GD Double circulating pump gaskets for glycol >30%
  • FA Antifreeze heater for tank
  • FN Antifreeze heater for pipes
  • FO Antifreeze heater for tank and pipes
  • FG Antifreeze heater for single pump and pipes
  • FM Antifreeze heater for double pump and pipes
  • FUM Antifreeze heater for tank, single pump and pipes
  • FDM Antifreeze heater for tank, double pump and pipes
  • SS Soft start
  • IS Modbus RTU protocol, RS485 serial interface
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • HYM Hybrid systems management
  • DHW Domestic hot water management
  • MN High and low pressure gauges

Loose accessories

  • CR Remote control panel
  • RP Coils protection metallic guards
  • AG Rubber shock absorbers
  • AM Spring shock absorbers
051061071081091101111131152172
HeatingHeating capacity (1)kW55,763,671,481,694,2109124142163197
Absorbed power (1)kW16,919,521,824,428,233,337,243,249,959,0
COP (1)3,303,263,283,343,343,273,333,293,273,34
Heating (EN14511)Heating capacity (1)kW55,963,871,681,894,4109124142163197
Absorbed power (1)kW17,119,822,124,828,633,737,744,050,759,9
COP (1)3,263,223,233,303,303,243,293,243,223,29
SCOP (2)3,433,393,383,503,523,423,443,413,403,39
Energy Efficiency (2)%134132132137138134135133133132
Energy Class (3)A+A+A+A+------
CoolingCooling capacity (4)kW48,254,962,571,982,894,5108125139163
Absorbed power (4)kW15,818,720,723,728,432,035,641,848,056,2
EER (4)3,052,943,023,032,922,953,032,992,902,90
Cooling (EN14511)Cooling capacity (4)kW48,154,862,471,882,694,4108125139163
Absorbed power (4)kW16,018,920,923,928,732,336,042,348,656,9
EER (4)3,012,902,983,002,882,933,002,952,852,86
SEER (5)3,953,843,963,973,923,863,974,023,873,88
Energy Efficiency (5)%155151155156154151156158152152
CompressorQuantity2222233344
Refrigerant circuits1111111122
Capacity steps2222233344
EvaporatorWater flowl/s2,302,622,983,433,954,505,155,966,637,77
Pressure dropskPa28303128282329393837
Water connections"G1 ½"1 ½"1 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"
Electrical characteristicsPower supplyV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Max. running currentA41445560677986101116131
Max. starting currentA164166179192235202218268248298
Unit with tank and pumpPump available static pressurekPa155150140135155200190170165155
Tank water volumel400400400400400400400400600600
Water connections"G2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"2 ½"
ECH fan available static pressureSTD versionsPa70601001001009560656065
SSL versionsPa70606560609560606060
Sound pressureSTD versions (6)dB(A)62626565656768686970
With SL accessory (6)dB(A)60606363636566666768
WeightsTransport weight (7)kg6356446937608079261076112612351414
Operating weight (7)kg6406507007708209401090114012501430

Dimensions

051061071081091101111131152172
LSTDmm2350235023502350235023503550355035503550
SSLmm2350235023502350235035503550470047004700
WSTD-SSLmm1100110011001100110011001100110011001100
HSTD-SSLmm1950195019502250225022502250225022502250

Notes

  • 1 Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b.
  • 2 Seasonal energy efficiency of heating at low temperature with average climatic conditions. According to EU Regulation n. 813/2013.
  • 3 Seasonal energy efficiency class of heating at low temperature with average climatic conditions. According to EU Regulation n. 811/2013.
  • 4 Chilled water from 12 to 7 °C, ambient air temperature 35 °C.
  • 5 Seasonal energy efficiency of cooling at medium temperature. According to EU Regulation n. 2016/2281.
  • 6 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.
  • 7 Unit without tank and pump.
  • N.B. (1) Weights of SSL versions are specified on technical brochure.