JWR 14÷34 S/IK/P/A
High efficiency air cooled liquid Chillers and Heat Pumps with EC Inverter Plug-Fans, Inverter Scroll compressor and plate exchanger for indoor ducted installation












The high efficiency indoor liquid Chillers of the JWR 14÷34 S/IK/P/A series, with R410A refrigerant and EC Inverter Plug-Fans, are designed for small and medium domestic or service sector systems with particular difficulty in positioning units outside the building.
With a prepainted plate structure, these units can be combined with Fan Coil units or with intermediate heat exchangers for process cooling applications.
These units are equipped with particular technical and design adjustments that enable an immediate and efficient use, in addition to remarkably quiet operation and a significant useful head of the fan.
A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series.
The units are compliant to the ErP Regulation.
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- JWR - Cooling only
- JWR/WP - Reversible Heat Pump
Power range
- 12.0-36.0 kW
- 3.5-10.0 Ton
Features
- Self-supporting prepainted steel frame. Sound-proofed compressor compartment (14÷34).
- DC INVERTER Scroll compressor with internal overheat protection, crankcase heater and soundproofing cover (14÷34).
- High efficiency reverse blade EC INVERTER PLUG-FAN, with electronic speed control.
- Condenser made of copper tubes and aluminium finned coil, complete with condensate drain pan for WP version only.
- Evaporator AISI 316 stainless steel braze welded plates type, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
- Electronic expansion valve.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses, compressors (21÷20) and pump remote control switch.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to -20 °C in cooling mode. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation and high and low pressure transducers on cooling circuit.
- Functioning in heating mode with outside air temperature down to -15 °C.
- Microprocessor control and regulation system.
- Advanced functions: remote set-point with 0-10V signal, remote set-point with 4-20mA signal, remote signal for second set-point activation, demand limit from digital input, management of hybrid systems, management of domestic hot water production.
Accessories
Factory fitted accessories
- BT Low water temperature kit
- TX Coil with pre-coated fins
- PS Single circulating pump
- GS Single circulating pump gasket for glycol >30%
- FE Antifreeze heater for evaporator
Loose accessories
- CR Remote control panel
- IS Modbus RTU protocol, RS485 serial interface
- RP Coils protection metallic guards
- FP Coils protection metallic guards with filter
- AG Rubber shock absorbers
Technical data
14 | 16 | 18 | 20 | 24 | 27 | 34 | |||
Cooling | Cooling capacity (1) | kW | 12,4 | 15,7 | 19,0 | 22,4 | 25,8 | 30,5 | 35,9 |
Absorbed power (1) | kW | 4,3 | 5,4 | 6,5 | 7,7 | 9,3 | 10,3 | 12,1 | |
EER (1) | 2,88 | 2,91 | 2,92 | 2,91 | 2,77 | 2,96 | 2,97 | ||
Cooling (EN14511) | Cooling capacity (1) | kW | 12,4 | 15,7 | 19,0 | 22,3 | 25,8 | 30,4 | 35,8 |
Absorbed power (1) | kW | 3,9 | 5,1 | 6,2 | 7,4 | 8,4 | 9,4 | 11,3 | |
EER (1) | 3,14 | 3,10 | 3,07 | 3,02 | 3,08 | 3,24 | 3,18 | ||
SEER (2) | 4,32 | 4,30 | 4,23 | 4,33 | 4,32 | 4,10 | 4,12 | ||
Energy Efficiency (2) | % | 170 | 169 | 166 | 170 | 170 | 161 | 162 | |
Heating | Heating capacity (3) | kW | 14,1 | 17,5 | 20,9 | 24,8 | 28,7 | 34,3 | 40,4 |
Absorbed power (3) | kW | 4,5 | 5,4 | 6,4 | 7,5 | 9,4 | 10,7 | 12,6 | |
COP (3) | 3,13 | 3,24 | 3,27 | 3,31 | 3,05 | 3,21 | 3,21 | ||
Heating (EN14511) | Heating capacity (3) | kW | 14,2 | 17,6 | 21,0 | 24,9 | 28,8 | 34,4 | 40,5 |
Absorbed power (3) | kW | 4,2 | 5,1 | 6,1 | 7,2 | 8,5 | 9,8 | 11,8 | |
COP (3) | 3,40 | 3,46 | 3,44 | 3,45 | 3,39 | 3,50 | 3,43 | ||
SCOP (4) | 3,58 | 3,57 | 3,68 | 3,70 | 3,91 | 4,08 | 3,79 | ||
Energy Efficiency (4) | % | 140 | 140 | 144 | 145 | 153 | 160 | 149 | |
Energy Class (5) | A+ | A+ | A+ | A+ | A++ | A++ | A+ | ||
SCOP (6) | 2,89 | 2,84 | 2,87 | 2,86 | 2,92 | 2,93 | 2,90 | ||
Energy Efficiency (6) | % | 113 | 111 | 112 | 111 | 114 | 114 | 113 | |
Energy Class (7) | A+ | A+ | A+ | A+ | A+ | A+ | A+ | ||
Compressor | Quantity | n° | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Evaporator | Water flow | l/s | 0,59 | 0,75 | 0,91 | 1,07 | 1,23 | 1,45 | 1,71 |
Pressure drops | kPa | 25 | 20 | 29 | 30 | 20 | 29 | 31 | |
Water connections | "G | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | |
Fan available static pressure | Pa | 115 | 115 | 115 | 115 | 150 | 150 | 150 | |
Electrical characteristics | Power supply | V/Ph/Hz | 400/3+N/50 | 400/3+N/50 | 400/3+N/50 | 400/3+N/50 | 400/3+N/50 | 400/3+N/50 | 400/3+N/50 |
Max. running current | A | 14 | 14 | 16 | 19 | 22 | 22 | 25 | |
Max. starting current | A | 9 | 9 | 10 | 11 | 12 | 12 | 13 | |
Unit with pump | Pump available static pressure | kPa | 76 | 82 | 70 | 60 | 140 | 115 | 150 |
Water connections | "G | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | 1 ¼" | |
Sound pressure | (8) | dB(A) | 58 | 58 | 59 | 61 | 62 | 63 | 64 |
Weights | Transport weight | kg | 203 | 213 | 215 | 217 | 353 | 359 | 374 |
Operating weight | kg | 205 | 215 | 217 | 219 | 356 | 362 | 377 |
Dimensions
14 | 16 | 18 | 20 | 24 | 27 | 34 | |||
L | STD | mm | 900 | 900 | 900 | 900 | 1500 | 1500 | 1500 |
W | STD | mm | 690 | 690 | 690 | 690 | 800 | 800 | 800 |
H | STD | mm | 1750 | 1750 | 1750 | 1750 | 1600 | 1600 | 1600 |
Notes
- 1 Chilled water from 12 to 7 °C, ambient air temperature 35 °C.
- 2 Seasonal energy efficiency of cooling at low temperature. According to EU Regulation n. 2016/2281.
- 3 Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b.
- 4 Seasonal energy efficiency of heating at low temperature with average climatic conditions. According to EU Regulation n. 813/2013.
- 5 Seasonal energy efficiency class of heating at low temperature with average climatic conditions. According to EU Regulation n. 811/2013.
- 6 Seasonal energy efficiency of heating at medium temperature with average climatic conditions. According to EU Regulation n. 813/2013.
- 7 Seasonal energy efficiency class of heating at medium temperature with average climatic conditions. According to EU Regulation n. 811/2013.
- 8 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.