TWA/WP 212÷682 S/K/P/A

A CLASS energy efficiency aircooled reversible Heat Pumps with axial fans, Scroll compressors and plate exchanger

_icona_clint_solo_raffreddamento-riscaldamento_2024.png _icona_clint_compressore_scroll_2024.png _icona_clint_fan_assiale_2024.png _icona_clint_exchanger_plate_2024.png _icona_clint_solution_A_class_heating_2024.png _icona_clint_refrigerant_R410A_2024.png _icona_clint_refrigerant_R452B_2024.png _icona_clint_refrigerant_R454B_2024.png

The TWA/WP 212÷682 S/K/P/A reversible Heat Pumps are characterized by A CLASS energy efficiency.
The units are characterized by multi-compressor design on double cooling circuit, to reach high energy performances, reduction of current at start-up, elimination of inertial tanks and excellent silent functioning. The use of components built in large series makes them highly reliable and the management of a high number of compressors allows increased life span with reduction of machine stopping risks and easier maintenance operations.
Are available as option the new EC Inverter fans with high available static pressure and efficiency.
The units are designed for hot water production up to 55°C.
The units are compliant to the ErP Regulation.

On request, units can be supplied with R452B or R454B refrigerant.

Versions

  • TWA/WP - Reversible Heat Pump
  • TWA/WP/SSL - Super silenced reversible Heat Pump

Power range

  • 227-762 kW
  • 65.0-217 Ton

Features

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Axial fans directly coupled to an electric motor with external rotor.
  • Condenser made of copper tubes and aluminium finned coils.
  • Evaporator AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch. On the units it is always installed an antifreeze heater.
  • Cooling circuit shut-off valve on liquid line in 302÷682 models.
  • Electronic expansion valve.
  • Electronic high and low pressure gauges.
  • R410A refrigerant. On request R452B or R454B refrigerant.
  • Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, thermal protection relays for compressors and thermocontacts for fans.
  • Functioning in heating mode with outside air temperature down to -15 °C.
  • Microprocessor control and regulation system.

Factory fitted accessories

  • ISB BACnet MSTP protocol, RS485 serial interface
  • GS Single circulating pump gasket for glycol >30%
  • GD Double circulating pump gaskets for glycol >30%
  • FN Antifreeze heater for pipes
  • FG Antifreeze heater for single pump and pipes
  • FM Antifreeze heater for double pump and pipes
  • SS Soft start
  • IS Modbus RTU protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • PDI Inverter double circulating pump
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • MN High and low pressure gauges
  • IM Automatic circuit breakers
  • PD Double circulating pump
  • PSI Inverter single circulating pump
  • PS Single circulating pump
  • EW External water connections
  • TX Coil with pre-coated fins
  • RT Total heat recovery
  • DS Desuperheater
  • ECH EC Inverter fans with high available static pressure
  • EC EC Inverter fans
  • BT Low water temperature kit
  • CC Condensing control down to -20 °C
  • CT Condensing control down to 0 °C
  • RFL Cooling circuit shut-off valve on liquid line
  • RFM Cooling circuit shut-off valve on discharge line
  • SL Unit silencement

Loose accessories

  • CR Remote control panel
  • RP Coils protection metallic guards
  • AG Rubber shock absorbers
  • AM Spring shock absorbers
212222242272302342362412442482562622682
HeatingHeating capacity (1)kW227256272294342369389420476532566677762
COP (1)3,443,413,363,463,353,483,473,363,383,393,353,353,37
Heating (EN14511)Heating capacity (1)kW227257272294343370390421477533567678763
COP (1)3,383,353,313,413,303,443,423,313,333,353,313,323,34
SCOP (2)3,403,473,403,393,423,393,403,413,373,413,363,383,48
Energy Efficiency (2)%133136133133134133133133132133131132136
CoolingCooling capacity (3)kW195217239259294322339359421475512597671
EER (3)2,912,893,063,052,943,013,002,832,922,932,982,882,78
Cooling (EN14511)Cooling capacity (3)kW195217239259294322339359421475512597671
EER (3)2,872,853,023,012,902,982,972,792,892,912,952,862,76
SEER (4)4,054,064,104,114,074,074,084,354,424,454,554,554,55
Energy Efficiency (4)%159159161161160160160171174175179179179
CompressorQuantity3+33+33+33+34+44+44+45+55+56+66+66+66+6
Refrigerant circuits2222222222222
Capacity steps66668888810101010
EvaporatorWater flowl/s9,2910,3411,3912,3414,0115,3516,1617,1120,0722,6424,4028,4531,98
Pressure dropskPa44554238493741464632373330
Water connectionsDN808080808080808080150150150150
Electrical characteristicsPower supplyV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Max. running currentA158171187202231247262283329366397462520
Max. starting currentA281304354370363414429415497533564650707
Unit with pumpPump available static pressurekPa155130205195185185175160135185175160150
Water connectionsDN100100100100100100100100100100100150150
Sound pressureSTD version (5)dB(A)72717172727374747676767678
With SL accessory (5)dB(A)69686869697071717373737375
SSL version (5)dB(A)65,065,065,066,066,067,067,067,068,069,070,0------
WeightsTransport weightkg1954229124092437256728202830301931643702383246604698
Operating weightkg1970231024302460259028502860305032003750388047204770

Dimensions

212222242272302342362412442482562622682
LSTDmm2800400040004000400050005000500050006200620072007200
SSLmm40004000500050005000500050005000620062007200------
WSTD/SSLmm2200220022002200220022002200220022002200220022002200
HSTD/SSLmm2100210021002100210021002100210021002100210021002100

Notes

  • 1 Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b.
  • 2 Seasonal energy efficiency of heating at low temperature with average climatic conditions. According to EU Regulation n. 813/2013.
  • 3 Chilled water from 12 to 7 °C, ambient air temperature 35 °C.
  • 4 Seasonal energy efficiency of cooling at low temperature. According to EU Regulation n. 2016/2281.
  • 5 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.
  • N.B. (1) Weights of SSL version are specified on technical brochure.