TWA/FC 212÷1102 S/K/P
Air cooled liquid chillers Free-Cooling with axial fans, Scroll compressors and plate exchanger
- Fans: Axial, EC axial
- Compressors: Scroll
- Refrigerant: R410A, R452B, R454B
- Exchangers: Plate
The units are compliant to the 2021 ErP Regulation for process cooling application.
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- TWA/FC - Cooling only
Power range
- 208-1102 kW
- 59,0-313 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coils combined with FREE-COOLING coils.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Evaporator AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch.
- Cooling circuit shut-off valve on liquid line in 302÷1102 models.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, thermal protection relays for compressors and thermocontacts for fans.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to –20 °C. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation, high and low pressure transducers on cooling circuit and an electrical heater on electrical board.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- RFM Cooling circuit shut-off valve on discharge line
- RFL Cooling circuit shut-off valve on liquid line
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- TX Coil with pre-coated fins
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- SS Soft start
- WM Web Monitoring - Wireless remote monitoring (4G)
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISBT BACnet IP protocol, Ethernet port
- ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
- ISBT1 BACnet IP protocol, Ethernet port, BTL certified
- ISS SNMP protocol, Ethernet port
- MTS Master/Slave Network Management
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
- Product overview (IT) clint_overview_ITA_2025_w.pdf
- Product overview (EN) clint_overview_ENG_2025_w.pdf
- Specification items (EN) 19_Specification_items_CHA_K_FC_726P_36012P.docx
- Specification items (IT) 19_Voci_di_capitolato_CHA_K_FC_726P_36012P.docx
- Installation, use and maintenance manuals (IT) IT__CHA_K_726-P_36012-P__CLM_41.7__3_s5qRPfJ.pdf
- Installation, use and maintenance manuals (IT) IT__CHA_G_FC_726-P_36012-P__CLM_48.8__6.pdf
- Installation, use and maintenance manuals (IT) IT__CHA_L_FC_726-P_36012-P__CLM_48.8__6.pdf
- Installation, use and maintenance manuals (IT) IT__Gestione_Rete_Master_Slave__CL__0_2_Yzk41Ec.pdf
- Installation, use and maintenance manuals (EN) EN__CHA_K_FC_726-P_36012-P__CLM_48.7__4_DNwxb0G.pdf
- Installation, use and maintenance manuals (EN) EN__CHA_G_FC_726-P_36012-P__CLM_48.8__6.pdf
- Installation, use and maintenance manuals (EN) EN__CHA_L_FC_726-P_36012-P__CLM_48.8__6_V2Ixt2H.pdf
- Installation, use and maintenance manuals (EN) Rubber_shock_absorbers__CL_Rev1_EN.pdf
- Installation, use and maintenance manuals (EN) 02_EN__Spring_shock_absorbers__AM.pdf
- Installation, use and maintenance manuals (EN) 06_EN__Coils_treatments.pdf
- Installation, use and maintenance manuals (EN) EN__Master_Slave_Network_Management__CL__0_3.pdf
- Installation, use and maintenance manuals (DE) DE__CHA_K_FC_726-P_36012-P__CLM_48.7__4.pdf
- Installation, use and maintenance manuals (DE) DE__CHA_G_FC_726-P_36012-P__CLM_48.8__6_ByA76pk.pdf
- Installation, use and maintenance manuals (DE) DE__CHA_L_FC_726-P_36012-P__CLM_48.8__6.pdf
- Installation, use and maintenance manuals (FR) FR__CHA_K_FC_726-P_36012-P__CLM_48.7__4.pdf
- Installation, use and maintenance manuals (FR) FR__CHA_G_FC_726-P_36012-P__CLM_48.8__6.pdf
- Installation, use and maintenance manuals (FR) FR__CHA_L_FC_726-P_36012-P__CLM_48.8__6.pdf
- Installation, use and maintenance manuals (ES) ES__CHA_K_FC_726-P_36012-P__CLM_48.7__4.pdf
- Installation, use and maintenance manuals (ES) ES__CHA_G_FC_726-P_36012-P__CLM_48.8__6.pdf
- Installation, use and maintenance manuals (ES) ES__CHA_L_FC_726-P_36012-P__CLM_48.8__6.pdf
- Product guides (EN) KTK_Product_Guide_ENG_02_2025.pdf
- Technical brochures 32_twa-fc_212-1102_s-k-p_ktb_48.7.pdf
- Specification items (EN) 29_Specification_items_TWA_FC_212_1102_S_K_P.docx
- Installation, use and maintenance manuals (EN) 62__EN____TWA_FC_212_1102_S_K_P__KTM_48.7__4.pdf
- Installation, use and maintenance manuals (EN) 64__EN____TWA_FC_212_1102_S_L_P__KTM_48.8__6.pdf
- Installation, use and maintenance manuals (EN) 63__EN____TWA_FC_212_1102_S_G_P__KTM_48.8__6.pdf
- Installation, use and maintenance manuals (DE) 62__DE____TWA_FC_212_1102_S_K_P__KTM_48.7__4.pdf
- Installation, use and maintenance manuals (DE) 63__DE____TWA_FC_212_1102_S_G_P__KTM_48.8__6.pdf
- Installation, use and maintenance manuals (DE) 64__DE____TWA_FC_212_1102_S_L_P__KTM_48.8__6.pdf