JWA 051÷172 S/K/P
Air cooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger
The liquid Chillers and Heat Pumps of the JWA 051÷172 S/K/P series, with R410A refrigerant, are designed for medium-sized service sector or industrial ambients.
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- JWA - Cooling only
- JWA/WP - Reversible Heat Pump
- JWA/SSL - Super silenced cooling only
- JWA/WP/SSL - Super silenced reversible Heat Pump
Power range
- 48,0-178 kW
- 14,0-51,0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coil.
- Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side in 051÷131 models; with two independent circuits on the refrigerant side and one on the water side in 152÷172 models, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- RFM Cooling circuit shut-off valve on discharge line
- RFL Cooling circuit shut-off valve on liquid line
- CT Condensing control down to 0 °C
- CC Condensing control down to -20 °C
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- DS Desuperheater
- RT Total heat recovery
- TX Coil with pre-coated fins
- SI Inertial tank
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- FE Antifreeze heater for evaporator
- FN Antifreeze heater for pipes
- FO Antifreeze heater for tank and pipes
- FG Antifreeze heater for single pump and pipes
- FM Antifreeze heater for double pump and pipes
- FUM Antifreeze heater for tank, single pump and pipes
- FDM Antifreeze heater for tank, double pump and pipes
- SS Soft start
- IS Modbus RTU protocol, RS485 serial interface
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- FP Coils protection metallic guards with filter
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
- Product guides (EN) KTK_Product_Guide_ENG_02_2025.pdf
- Commercial leaflets ktk_dpl_aqua_plus_2025_ktd_163_w.pdf
- Technical brochures 08_jwa_051-172_s-k-p_ktb_61.7_IyYqVbb.pdf
- Specification items (EN) 08_Specification_items_JWA_051_172_S_K_P.docx
- Installation, use and maintenance manuals (EN) 16__EN____JWA_051_172_S_K_P__KTM_61.7__8.pdf
- Installation, use and maintenance manuals (EN) 17__EN____JWA_051_172_S_G_P__KTM_61.1__6.pdf
- Installation, use and maintenance manuals (EN) 18__EN____JWA_051_172_S_L_P__KTM_61.1__6.pdf
- Installation, use and maintenance manuals (DE) 16__DE____JWA_051_172_S_K_P__KTM_61.7__8.pdf
- Installation, use and maintenance manuals (DE) 18__DE____JWA_051_172_S_L_P__KTM_61.1__6.pdf
- Installation, use and maintenance manuals (DE) 17__DE____JWA_051_172_S_G_P__KTM_61.1__6.pdf