JWA 051÷172 S/K/P/AF
High efficiency air cooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger
The units are compliant to the ErP Regulation.
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- JWA - Cooling only
- JWA/WP - Reversible Heat Pump
- JWA/SSL - Super silenced cooling only
- JWA/WP/SSL - Super silenced reversible Heat Pump
Power range
- 51,0-183 kW
- 15,0-52,0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coil.
- Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side in 051÷131 models; with two independent circuits on the refrigerant side and one on the water side in 152÷172 models, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
- Functioning in heating mode with outside air temperature down to -15 °C.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- RFM Cooling circuit shut-off valve on discharge line
- RFL Cooling circuit shut-off valve on liquid line
- CT Condensing control down to 0 °C
- CC Condensing control down to -20 °C
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- DS Desuperheater
- RT Total heat recovery
- TX Coil with pre-coated fins
- SI Inertial tank
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- FE Antifreeze heater for evaporator
- FN Antifreeze heater for pipes
- FO Antifreeze heater for tank and pipes
- FG Antifreeze heater for single pump and pipes
- FM Antifreeze heater for double pump and pipes
- FUM Antifreeze heater for tank, single pump and pipes
- FDM Antifreeze heater for tank, double pump and pipes
- SS Soft start
- IS Modbus RTU protocol, RS485 serial interface
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- HYM Hybrid systems management
- DHW Domestic hot water management
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- FP Coils protection metallic guards with filter
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
- Product guides (EN) KTK_Product_Guide_ENG_02_2025.pdf
- Commercial leaflets ktk_dpl_aqua_plus_2025_ktd_163_w.pdf
- Technical brochures 06_jwa_051-172_s-k-p-af_ktb_198.pdf
- Specification items (EN) 06_Specification_items_JWA_051_172_S_K_P_AF.docx
- Installation, use and maintenance manuals (EN) 11__EN____JWA_051_172_S_G_P_AF__KTM_198.1__7.pdf
- Installation, use and maintenance manuals (EN) 10__EN____JWA_051_172_S_K_P_AF__KTM_198__8.pdf
- Installation, use and maintenance manuals (EN) 12__EN____JWA_051_172_S_L_P_AF__KTM_198.1__7.pdf
- Installation, use and maintenance manuals (DE) 10__DE____JWA_051_172_S_K_P_AF__KTM_198__8.pdf
- Installation, use and maintenance manuals (DE) 12__DE____JWA_051_172_S_L_P_AF__KTM_198.1__7.pdf