TWA/FC 212÷1102 S/K/P
Air cooled liquid chillers Free-Cooling with axial fans, Scroll compressors and plate exchanger
The units are compliant to the 2021 ErP Regulation for process cooling application.
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- TWA/FC - Cooling only
Power range
- 208-1102 kW
- 59,0-313 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coils combined with FREE-COOLING coils.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Evaporator AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch.
- Cooling circuit shut-off valve on liquid line in 302÷1102 models.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, thermal protection relays for compressors and thermocontacts for fans.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to –20 °C. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation, high and low pressure transducers on cooling circuit and an electrical heater on electrical board.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- RFM Cooling circuit shut-off valve on discharge line
- RFL Cooling circuit shut-off valve on liquid line
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- TX Coil with pre-coated fins
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- SS Soft start
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISB BACnet MSTP protocol, RS485 serial interface
- ISBT BACnet IP protocol, Ethernet port
- ISS SNMP protocol, Ethernet port
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
- Product guides (EN) KTK_Product_Guide_ENG_02_2025.pdf
- Technical brochures 32_twa-fc_212-1102_s-k-p_ktb_48.7.pdf
- Specification items (EN) 29_Specification_items_TWA_FC_212_1102_S_K_P.docx
- Installation, use and maintenance manuals (EN) 62__EN____TWA_FC_212_1102_S_K_P__KTM_48.7__4.pdf
- Installation, use and maintenance manuals (EN) 64__EN____TWA_FC_212_1102_S_L_P__KTM_48.8__6.pdf
- Installation, use and maintenance manuals (EN) 63__EN____TWA_FC_212_1102_S_G_P__KTM_48.8__6.pdf
- Installation, use and maintenance manuals (DE) 62__DE____TWA_FC_212_1102_S_K_P__KTM_48.7__4.pdf
- Installation, use and maintenance manuals (DE) 63__DE____TWA_FC_212_1102_S_G_P__KTM_48.8__6.pdf
- Installation, use and maintenance manuals (DE) 64__DE____TWA_FC_212_1102_S_L_P__KTM_48.8__6.pdf