TWA 212÷1102 S/K/P
Aircooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger
The liquid Chillers and Heat Pumps of the TWA 212÷1102 S/K/P series, with R410A refrigerant, are designed for large-sized service sector or industrial ambients.
The units are characterized by multi-compressor design on double cooling circuit, to reach high energy performances, reduction of current at start-up, elimination of inertial tanks and excellent silent functioning. The use of components built in large series makes them highly reliable and the management of a high number of compressors allows increased life span with reduction of machine stopping risks and easier maintenance operations.
Are available as option the new EC Inverter fans with high available static pressure and efficiency.
Cooling only units are compliant to the ErP 2021 Regulation for process cooling application; for comfort cooling application they are compliant if provided with EC or ECH accessory (EC Inverter fans).
Heat pump models 726-P÷13010-P are compliant to the ErP Regulation; models
15010-P÷36012-P are compliant if provided with EC or ECH accessory (EC Inverter fans).
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- TWA - Cooling only
- TWA/WP - Reversible Heat Pump
- TWA/SSL - Super silenced cooling only
Power range
- 199-1051 kW
- 57,0-299 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coils.
- Evaporator AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
- Cooling circuit shut-off valve on liquid line in 302÷1102 models.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, thermal protection relays for compressors and thermocontacts for fans.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- ISB BACnet MSTP protocol, RS485 serial interface
- GD Double circulating pump gaskets for glycol >30%
- FE Antifreeze heater for evaporator
- FN Antifreeze heater for pipes
- FG Antifreeze heater for single pump and pipes
- FM Antifreeze heater for double pump and pipes
- SS Soft start
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- GS Single circulating pump gasket for glycol >30%
- ISBT BACnet IP protocol, Ethernet port
- ISS SNMP protocol, Ethernet port
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- MN High and low pressure gauges
- DS Desuperheater
- SL Unit silencement
- RFM Cooling circuit shut-off valve on discharge line
- RFL Cooling circuit shut-off valve on liquid line
- CT Condensing control down to 0 °C
- CC Condensing control down to -20 °C
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- IM Automatic circuit breakers
- RT Total heat recovery
- TX Coil with pre-coated fins
- EW External water connections
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- FP Coils protection metallic guards with filter
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
- Product overview (EN) _ktk_dpl_over_2022_ENG_w.pdf
- Product guides (EN) KTK_Product_Guide_ENG_05_2022.pdf
- Commercial leaflets (EN) _ktk_dpl_low_gwp_refrigerants_technical_handbook_ENG_07.2022.pdf
- Commercial leaflets (EN) _ktk_dpl_low_gwp_refrigerants_commercial_ENG_07.2022.pdf
- Technical brochures 31_twa_212-1102_s-k-p_ktb_41.7_TblseJx.pdf
- Installation, use and maintenance manuals (IT) IT_TWA_212_1102_S_K_P__KTM-41.7_REV2.pdf
- Installation, use and maintenance manuals (IT) IT_TWA_212_1102_S_G_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (IT) IT_TWA_212_1102_S_L_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (EN) EN_TWA_212_1102_S_K_P__KTM-41.7_REV2.pdf
- Installation, use and maintenance manuals (EN) EN_TWA_212_1102_S_G_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (EN) EN_TWA_212_1102_S_L_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (DE) DE_TWA_212_1102_S_K_P__KTM-41.7_REV2.pdf
- Installation, use and maintenance manuals (DE) DE_TWA_212_1102_S_G_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (DE) DE_TWA_212_1102_S_L_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (FR) FR_TWA_212_1102_S_K_P__KTM-41.7_REV2.pdf
- Installation, use and maintenance manuals (FR) FR_TWA_212_1102_S_G_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (FR) FR_TWA_212_1102_S_L_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (ES) ES_TWA_212_1102_S_K_P__KTM-41.7_REV2.pdf
- Installation, use and maintenance manuals (ES) ES_TWA_212_1102_S_G_P__KTM-41.8_REV4.pdf
- Installation, use and maintenance manuals (ES) ES_TWA_212_1102_S_L_P__KTM-41.8_REV4.pdf