URT/EC 051÷212 S/K

Double Skin packaged Roof Top units with Scroll compressors and EC Inverter Plug-Fans

_icona_clint_solo_raffreddamento_2024.png _icona_clint_solo_raffreddamento-riscaldamento_2024.png _icona_clint_compressore_scroll_2024.png _icona_clint_fan_plug_EC_inverter_2024.png _icona_clint_solution_doppio_pannello_2024.png _icona_clint_refrigerant_R410A_2024.png

The double skin packaged Roof Top units of this series are the ideal solution for the air conditioning of wide surface areas for public use such as halls, shopping centres, cafeterias, restaurants and health centres, or for industrial environments such as food processing or preservation centres. Those units feature Scroll compressors with R410A refrigerant and EC Inverter Plug-Fans. The EC Inverter Plug-Fans with high energy efficiency backward blades both for intake as well as delivery are managed by an electronic control adjusting fans' rotational speed to adapt the air flow to the system capacity.
Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in Cooling only and Reversible Heat Pump version.
The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards.
The units are compliant to the ErP Regulation.

Versions

  • URT/EC - Cooling only with EC Inverter Plug-Fans
  • URT/EC/WP - Reversible heat pump with Plug-Fans EC Inverter

Power range

  • 58,0-252 kW
  • 17,0-72,0 Ton

Features

  • Structure of base perimeter made of steel sheet elements galvanised. Frame made of extruded aluminium alloy profiles connected by 3 way joints. Assembling of the base to the frame is of dual support and grants the walking on the base panels installation without sticking out screws. 50mm thick sandwich panels made of prepainted steel sheet; water proofing granted by gaskets having shape memory for perfect seal up even after repeated removals. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser and evaporator with copper tube and aluminium finned coil.
  • R410A refrigerant.
  • Electrical board includes: door interlocking isolator, fuses, thermal protection relays on compressors, thermocontacts for the fans of the condensing unit and contactors for the fan motors of the air handling unit.
  • Microprocessor for the automatic control of the unit.

Factory fitted accessories

  • IM Automatic circuit breakers
  • SL Unit silencement
  • RFM Cooling circuit shut-off valve on discharge line
  • RFL Cooling circuit shut-off valve on liquid line
  • CT Condensing control down to 0 °C
  • CC Condensing control down to -20 °C
  • ECA EC Inverter fans on condensing section
  • TXC Condensing coil with pre-coated fins
  • TXE Evaporating coil with pre-coated fins
  • FT/M6 Soft bag filters efficency ePM10 70% (M6)
  • FT/M7 Soft bag filters efficency ePM2.5 70% (F7)
  • FT/M8 Soft bag filters efficency ePM1 70% (F8)
  • FT/R6 Rigid bag filters efficency ePM10 70% (M6)
  • FT/R7 Rigid bag filters efficency ePM1 50% (F7)
  • FT/R8 Rigid bag filters efficency ePM1 70% (F8)
  • FT/E Electrostatic filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • AT/C Control adjustment of the air flow according to the load
  • WS2 Hot water coil with 3-Way valve
  • EHG Electrical heater with step regulation
  • SSA Active sanitation systems for air and rooms
  • PF Differential pressure switch filters control
  • SB Fire sensor
  • SC Smoke sensor
  • IS Modbus RTU protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • CP Potential free contacts
  • RP Coils protection metallic guards
  • MN High and low pressure gauges

Loose accessories

  • CR Remote control panel
  • AG Rubber shock absorbers